4/08

[New!] Catalog and Price List PDF:  2 MB / 15 pages    Posted 11 April 2008

9/07

Soil Moisture Sensors for environmental, agricultural and botanical applications.

5/07

Solar Radiation Sensor for environmental, agricultural, botanical and solar energy applications.

Millivolt Module (0-96 millivolts) for XR440 Data Logger

1/06

DC Current Sensors Two current ranges available: +/-50 amps and +/-100 amps.

9/05

P300 Low Pressure Sensor +/-1milliBar (+/-0.4 inch H2O).

3/05

PT520 High Temperature RTD Sensor with a continuous temperature rating of 260°C (500°F).

XR5-SE Data Loggers with optional millivolt and thermocouple inputs.

12/04

P300 Barometric Pressure Sensor  Pressure range of 600-1100 millibar.

10/2004

PT956 Waterproof Temperature Probe  Suitable for burial in soil and liquid immersion applications.

7/2004

Additional ranges for P1510 Pressure Sensors  0-25 psig and 0-50 psig.

5/2004

Updated Software and Firmware for XR5 Data Loggers

Pocket Logger Software V3.18

4/2004

P1510 Pressure Sensors

1/2004

EC44 Compact Weatherproof Case

11/2003

Bipolar Voltage Ranges as high as +/-60V for XR440 Data Logger

P1500 Pressure Sensors

High Temperature RTD Probe for XR440 Data Logger

7/2003

Millivolt Module (0-20millivolts) for XR440 Data Logger

Updated Free Software for XR5 Data Loggers

6/2003

Pocket Logger Software V3.17

5/2003

Free Software for XR5 Data Loggers

3/2003

XR5 Data Loggers

8/2002

New P300 Pressure Range  Our P300 series Pressure Transducer now has a new stocked pressure range of ±30 inch H2O Differential.

4/2002

New Pressure Range  Our P1000 series Pressure Transducer will be available soon in a new stocked pressure range of 0-5 psig.

9/2001

Pocket Logger Software V3.15  Pocket Logger Graphs now display full-screen on high-resolution monitors. Runs on Win95/98/ME/2000/NT/XP.

6/2001 

We have moved!  To better serve our customers Pace Scientific has moved to a larger facility.  Our new address is:

Pace Scientific Inc.

PO Box 4418

Mooresville, NC 28117

Tel: 704-799-0688

Fax: 704-799-0177

9/2000

Watt Hour Sensors Accurate to 1%, split core design, no external power required.

8/2000

Pocket Logger Software V3.10 New features include an Auto Data Export mode which automatically creates an ASCII CSV file (compatible with Excel and other programs) when the Pocket Logger's data is transferred to a PC.

6/2000

High Accuracy Pressure Transducers  P1000 Series - All Stainless Steel (no o-rings or seals) with 0.25% Accuracy.  No external power source required.  Initially available in one of two pressure ranges: VAC (-15) to 120 psig, and VAC (-15) to 600 psig.  Availability: Stock

12/99

Pocket Logger Software V3.09 supports long file names and includes a command line interface for programmers. For Windows 95/98/NT. A 16 bit version is available for Win 3.1 users.

5/99

XR440 extended temperature range.
Operation to -40°C is now a standard feature of the XR440 Pocket Logger.

3/99

Pocket Logger Software V3.08
Y2000 Compliant. New for Version 3.08 is a Real Time 'Strip Chart' Graphing mode. The full version may be downloaded and freely distributed by our customers and anyone interested in our products - no strings attached!
CE Mark
The XR440 Pocket Logger and most PACE Sensors are CE approved to EN50081-1 (RF emissions) and EN50082-1 (ESD and RF immunity). The CE Mark is required on all electronic products shipped to member countries of the European Union.
1/99
 
Thermocouple / Millivolt Modules
Includes internal amplifier and precision thermistor for cold-junction compensation and/or ambient temperature. Available ranges include ±11 mv, ±22 mv, and 0-50 mv. Use with Thermocouple Type J, K, N, R, S, T, B, C, and E.
12/98
Temperature / Humidity Plug-in Module
Miniature plug-in provides one-piece Temp / RH / Wet Bulb / Dew Point logging solution. Two spare channels are available for other PACE sensors or signals.
Temperature / Humidity / Light Plug-in Module
Miniature plug-in provides one-piece Temp / RH / Wet Bulb / Dew Point and Light logger. One spare channel is available for a PACE sensor or signal.
11/98
 
0-60 vdc Input Range
Pocket Loggers can monitor and record 0-60 vdc signals using the Input Scaling Module.
 
8/98
 
P3000 Pressure Sensors
Features include 1% accuracy and stainless steel wetted parts. Connect to any Pocket Logger input channel, no external power required. Very low power draw. Log pressure data for over 2 years, powered totally by the Pocket Logger's internal user-replaceable battery, even with four P3000's connected to one logger! Available in 0-100, 0-250 and 0-600 psig pressure ranges.
 
7/98
 
Pocket Logger Software V3.07
Year 2000 compliant. Easy to use data graphing and control program supports all PACE Pocket Loggers. Handles very large 'csv' type data files. The full version may be downloaded and freely distributed by our customers and anyone interested in our products - no strings attached!
 
 
4/98
 
XR440 Pocket Logger
New features include selectable resolution, 200 year data retention, up to 129,024 reading storage capacity (-M option), and operation to -40°C (-T option).
 
 
Pocket Logger Software V3.06
Supports new features of XR440 Pocket Logger, plus enhanced communications for cellular and land-line modems.
 
 
11/97
 
EC506 Weatherproof Case
Protects Pocket Logger in outdoor or hostile environments.
 
PT940 Temperature Probe
Suitable for soil temperature monitoring and wet environments.
 
Relative Humidity Probe
Now stocked in three cable lengths, including a 20 FT (6 meter) shielded cable.
 
 
10/97
 
Smaller AC Current Sensor
Split-core SC100A Current Sensor now has 0.5" window size and 2.5" x 2.5" overall size.
 
8/97
 
Pocket Logger Software V3.05
New features include: Direct scaling for switch closures, moisture readings display as %RH, Wet Bulb or Dew Point; Expanded Help file.
 
5/97
 
PT933 Temperature Probe
Stainless Steel probe with 20 ft. cable and ±0.1° C. interchangeability.
 
2/97
 
Multi-range Input Scaling Module
Any combination of input ranges can now be specified on our Input Scaling Module.
 
30vdc input range
Pocket Loggers can record and monitor 0-30vdc signals using the Input Scaling Module.
 
 
1/97
 
Low Pressure Sensors
Our P300 Sensors include pressure ranges of 0-1 inch H2O and +/-1 inch H2O Connect to any Pocket Logger input channel, no external power required!
 
+/- 5vdc input range
Pocket Loggers can record and monitor bipolar +/-5vdc signals using the optional Input Scaling Module.
 
Trigger mode
Pocket Loggers can be set to start a logging session and/or to end a logging session based on the state of a trigger switch wired to channel 1. Channel 1 can be set to 'OFF' while being used as a trigger to maximize the storage capacity of the 'ON' channels. The connected or detached state of a temperature probe can also be used as the trigger.
 